| @@ -0,0 +1,296 @@ | ||
| """Models for OmniLogic chlorinator diagnostic responses.""" | ||
|
|
||
| from __future__ import annotations | ||
|
|
||
| import math | ||
| from typing import ClassVar, Self | ||
|
|
||
| from pydantic import BaseModel, ConfigDict, Field, PrivateAttr, ValidationError | ||
| from xmltodict import parse as xml_parse | ||
|
|
||
| from pyomnilogic_local.models.exceptions import OmniParsingError | ||
|
|
||
| _INVALID_DIAGNOSTIC_VALUE = 0xFFFF | ||
| _ADC_REFERENCE_VOLTAGE = 5 | ||
| _ADC_MAX_VALUE = 255 | ||
| _VOLTAGE_SCALE = 8.15 | ||
| _CURRENT_SCALE = 0.489 | ||
|
|
||
| # Lookup table used by OmniLogic to convert the cell and board thermistor ADC | ||
| # readings to tenths of a degree Fahrenheit. Values between entries are | ||
| # interpolated using the low three bits of the raw reading. | ||
| _TEMPERATURE_TENTHS_F = ( | ||
| 8000, | ||
| 3740, | ||
| 3136, | ||
| 2817, | ||
| 2603, | ||
| 2444, | ||
| 2318, | ||
| 2214, | ||
| 2125, | ||
| 2048, | ||
| 1980, | ||
| 1919, | ||
| 1864, | ||
| 1813, | ||
| 1767, | ||
| 1723, | ||
| 1683, | ||
| 1645, | ||
| 1610, | ||
| 1576, | ||
| 1544, | ||
| 1514, | ||
| 1485, | ||
| 1458, | ||
| 1431, | ||
| 1406, | ||
| 1381, | ||
| 1358, | ||
| 1335, | ||
| 1313, | ||
| 1291, | ||
| 1270, | ||
| 1250, | ||
| 1230, | ||
| 1211, | ||
| 1193, | ||
| 1174, | ||
| 1156, | ||
| 1139, | ||
| 1122, | ||
| 1105, | ||
| 1088, | ||
| 1072, | ||
| 1056, | ||
| 1041, | ||
| 1025, | ||
| 1010, | ||
| 995, | ||
| 980, | ||
| 966, | ||
| 951, | ||
| 937, | ||
| 923, | ||
| 909, | ||
| 895, | ||
| 881, | ||
| 868, | ||
| 854, | ||
| 841, | ||
| 828, | ||
| 815, | ||
| 802, | ||
| 789, | ||
| 776, | ||
| 763, | ||
| 750, | ||
| 737, | ||
| 725, | ||
| 712, | ||
| 699, | ||
| 687, | ||
| 674, | ||
| 661, | ||
| 649, | ||
| 636, | ||
| 624, | ||
| 611, | ||
| 598, | ||
| 586, | ||
| 573, | ||
| 560, | ||
| 547, | ||
| 534, | ||
| 521, | ||
| 508, | ||
| 495, | ||
| 482, | ||
| 469, | ||
| 455, | ||
| 442, | ||
| 428, | ||
| 414, | ||
| 400, | ||
| 386, | ||
| 372, | ||
| 357, | ||
| 342, | ||
| 327, | ||
| 312, | ||
| 297, | ||
| 281, | ||
| 265, | ||
| 248, | ||
| 231, | ||
| 214, | ||
| 196, | ||
| 178, | ||
| 159, | ||
| 140, | ||
| 120, | ||
| 99, | ||
| 77, | ||
| 54, | ||
| 31, | ||
| 6, | ||
| ) | ||
|
|
||
|
|
||
| def _combine_bytes(high_byte: int, low_byte: int) -> int: | ||
| return high_byte << 8 | low_byte | ||
|
|
||
|
|
||
| def _decode_temperature(raw_value: int) -> float | None: | ||
| if raw_value == 0: | ||
| return 0.0 | ||
| table_index, interpolation = divmod(raw_value, 8) | ||
| if raw_value >= _INVALID_DIAGNOSTIC_VALUE or table_index >= len(_TEMPERATURE_TENTHS_F) - 1: | ||
| return None | ||
|
|
||
| temperature = _TEMPERATURE_TENTHS_F[table_index] | ||
| if interpolation: | ||
| difference = temperature - _TEMPERATURE_TENTHS_F[table_index + 1] | ||
| temperature -= math.floor(((difference * interpolation * 10 / 8) + 5) / 10) | ||
| return temperature / 10 | ||
|
|
||
|
|
||
| class ChlorinatorDiagnosticParameter(BaseModel): | ||
| """A named value from a chlorinator diagnostic response.""" | ||
|
|
||
| model_config = ConfigDict(from_attributes=True) | ||
|
|
||
| name: str = Field(alias="@name") | ||
| data_type: str = Field(alias="@dataType") | ||
| value: int = Field(alias="#text") | ||
|
|
||
|
|
||
| class ChlorinatorDiagnosticResponse(BaseModel): | ||
| """Base model for parameter-based chlorinator diagnostic responses.""" | ||
|
|
||
| model_config = ConfigDict(from_attributes=True) | ||
| expected_response_name: ClassVar[str] | ||
| _raw: str = PrivateAttr(default="") | ||
|
|
||
| name: str = Field(alias="Name") | ||
| parameters: list[ChlorinatorDiagnosticParameter] = Field(alias="Parameters") | ||
|
|
||
| def get_param_by_name(self, name: str) -> int: | ||
| """Return a diagnostic parameter by its wire name.""" | ||
| parameter = next((parameter for parameter in self.parameters if parameter.name == name), None) | ||
| if parameter is None: | ||
| msg = f"Missing chlorinator diagnostic parameter: {name}" | ||
| raise OmniParsingError(msg) | ||
| return parameter.value | ||
|
|
||
| @classmethod | ||
| def load_xml(cls, xml: str) -> Self: | ||
| """Parse a chlorinator diagnostic XML response.""" | ||
| data = xml_parse(xml, force_list=("Parameter",)) | ||
| response_name = data.get("Response", {}).get("Name") | ||
| if response_name != cls.expected_response_name: | ||
|
Owner
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I don't understand what the point of all of this work to set and verify response names is? Are you concerned that it might send a request and somehow get a response intended for a different request? That doesn't happen. The way the protocol works, every request sent to the Omni via the async_send_and_receive method creates it's own datagram endpoint (so it's own local port), so responses sent from the omni will be sent to a port specific to that request. There are other (likely more efficient) ways to do this that I plan to look into in the future (involving using a single local port for sending and receiving responses, and matching responses with the transmitted message based on message IDs, etc), but for now, the fact that ever message sent uses a different local port disambiguates the responses. Was there some other reason for this response_name matching that I'm just not seeing? |
||
| msg = f"Expected {cls.expected_response_name} response, got {response_name!r}" | ||
| raise OmniParsingError(msg) | ||
| data["Response"]["Parameters"] = data["Response"]["Parameters"]["Parameter"] | ||
| try: | ||
| instance = cls.model_validate(data["Response"]) | ||
| instance._raw = xml | ||
| except ValidationError as exc: | ||
| msg = f"Failed to parse chlorinator diagnostics: {exc}" | ||
| raise OmniParsingError(msg) from exc | ||
| return instance | ||
|
|
||
|
|
||
| class ChlorinatorMeasurement(ChlorinatorDiagnosticResponse): | ||
| """Electrical, temperature, and salt measurements from a chlorinator cell.""" | ||
|
|
||
| expected_response_name = "GetCHLORMeasurementRsp" | ||
|
|
||
| @property | ||
| def pool_id(self) -> int: | ||
| """Body-of-water system ID.""" | ||
| return self.get_param_by_name("PoolID") | ||
|
|
||
| @property | ||
| def chlorinator_id(self) -> int: | ||
| """Physical chlorinator equipment ID.""" | ||
| return self.get_param_by_name("ChlorID") | ||
|
|
||
| def _combined_parameter(self, prefix: str) -> int: | ||
| return _combine_bytes(self.get_param_by_name(f"{prefix}HighByte"), self.get_param_by_name(f"{prefix}LowByte")) | ||
|
|
||
| @property | ||
| def voltage_raw(self) -> int: | ||
| """Raw cell-voltage ADC reading.""" | ||
| return self._combined_parameter("Voltage") | ||
|
|
||
| @property | ||
| def current_raw(self) -> int: | ||
| """Raw cell-current ADC reading.""" | ||
| return self._combined_parameter("Current") | ||
|
|
||
| @property | ||
| def cell_temperature_raw(self) -> int: | ||
| """Raw cell-temperature thermistor reading.""" | ||
| return self._combined_parameter("CellTemp") | ||
|
|
||
| @property | ||
| def board_temperature_raw(self) -> int: | ||
| """Raw controller-board temperature thermistor reading.""" | ||
| return self._combined_parameter("BoardTemp") | ||
|
|
||
| @property | ||
| def voltage(self) -> float | None: | ||
| """Cell voltage in volts, or None when the controller reports an invalid sentinel.""" | ||
| if self.voltage_raw >= _INVALID_DIAGNOSTIC_VALUE: | ||
| return None | ||
| return self.voltage_raw * _ADC_REFERENCE_VOLTAGE / _ADC_MAX_VALUE * _VOLTAGE_SCALE | ||
|
|
||
| @property | ||
| def current(self) -> float | None: | ||
| """Cell current in amperes, or None when the controller reports an invalid sentinel.""" | ||
| if self.current_raw >= _INVALID_DIAGNOSTIC_VALUE: | ||
| return None | ||
| return (self.current_raw * _ADC_REFERENCE_VOLTAGE / _ADC_MAX_VALUE) / _CURRENT_SCALE | ||
|
|
||
| @property | ||
| def cell_temperature_f(self) -> float | None: | ||
| """Cell temperature in degrees Fahrenheit, or None when invalid.""" | ||
| return _decode_temperature(self.cell_temperature_raw) | ||
|
|
||
| @property | ||
| def board_temperature_f(self) -> float | None: | ||
| """Controller-board temperature in degrees Fahrenheit, or None when invalid.""" | ||
| return _decode_temperature(self.board_temperature_raw) | ||
|
|
||
| @property | ||
| def instant_salt_level(self) -> int: | ||
| """Instantaneous salt level in parts per million.""" | ||
| return self._combined_parameter("InstantSaltLevel") | ||
|
|
||
| @property | ||
| def average_salt_level(self) -> int: | ||
| """Average salt level in parts per million.""" | ||
| return self._combined_parameter("AverageSaltLevel") | ||
|
|
||
|
|
||
| class ChlorinatorRelayPolarity(ChlorinatorDiagnosticResponse): | ||
| """Relay polarity reported by the physical chlorinator equipment.""" | ||
|
|
||
| expected_response_name = "GetCHLORRelayPolarityRsp" | ||
|
|
||
| @property | ||
| def pool_id(self) -> int: | ||
| """Body-of-water system ID.""" | ||
| return self.get_param_by_name("PoolID") | ||
|
|
||
| @property | ||
| def chlorinator_id(self) -> int: | ||
| """Physical chlorinator equipment ID.""" | ||
| return self.get_param_by_name("ChlorID") | ||
|
|
||
| @property | ||
| def relay_setting(self) -> int: | ||
| """Raw chlorinator relay polarity setting.""" | ||
| return self.get_param_by_name("RelaySetting") | ||
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
How were these values determined?